Tuttnauer 3870EAP Large Capacity Automatic Autoclave

Tuttnauer

Tuttnauer 3870EAP Large Capacity Automatic Autoclave

Web ID: 114
Product Number: 73870EAP

Need help choosing?

Speak to one of our expertly trained specialists!

Need help Financing?

Check out financing options from OnePlace Capital.

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The Tuttnauer 3870EAP autoclaves have a closed-door active drying system to maintain sterility and ensure efficient drying of packs and pouches. A high efficiency air pump circulates hot air after the sterilization cycle for fast drying. These steam sterilizers use a replaceable HEPA 0.2m air filter.

Features

  • New contemporary design with an easier to read bright blue display panel.
  • Pre-loaded cycles for: unwrapped instruments; wrapped/packs; liquid and additional drying cycle.
  • Cycle time is (hot) 40 minutes, (cold) 55 minutes.
  • The Chamber is 15" x 30" with a 22 gallon volume (85L), and holds 15 full standard cassettes.
  • All program parameters can be changed and stored.
  • Automatic shut off at the end of both the sterilization and dry cycles.
  • Audible and visual cycle interruption alert.
  • Double safety locking device prevents door from opening while chamber is pressurized.
  • Low water sensor prevents activation of sterilization cycle when there is insufficient water in the chamber or reservoir.
  • Constant monitoring of temperature and pressure for sterilization.
  • Power outage recovery system.
  • Door design prevents steam from coming in contact with control panel.
  • Optional printer.
  • High Efficiency air pump.
  • Decreased overall drying time.
  • Closed door drying.
  • Hepa filter 0.2μm air filter (replaceable)
  • Circulates hot air after the sterilization cycle for fast drying.

Warranty: 2 years parts and labor

Specifications

  • Chamber dimensions: 15” (384 mm) x 30” (760 mm)
  • Volume: 22 gallons | 85 Liters
  • Overall dimensions: 26” (665 mm) W x 34.5” (875 mm) D x 20.6” (525 mm) H
  • Standard cassettes: 15 full
  • Tray dimensions:
    • 11.3” (286 mm) W x 26.6” (675 mm) D x 1” (25 mm) H
    • 13.8” (350 mm) W x 26.6” (675 mm) D x 1” (25 mm) H
  • Number of trays: 2
  • Cold cycle time: 32 minutes
  • Hot cycle time: 23 minutes
  • Voltage: 230V
  • Frequency: 50/60 Hz
  • Power: 3000W
  • Current: 13.6A
  • Shipping weight: 213 lbs. (97 kg)