Force EZ™ Electrosurgical Generator with Instant Response™ Technology Instant Response™ Technology

Instant Response technology provides surgeons with improved performance or lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to "turn up the generator."

A Smoother Cut Through All Tissue Types

The Force EZ generator adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag.

Added Safety and Reliability Minimizes Electrosurgical Risks

Capacitive coupling is reduced by 30-50% when using Instant Response technology. This reduction is achieved by limiting the RMS voltage and the high frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.

What is Instant Response Technology?

Instant Response technology features an advanced feedback system that recognizes changes in tissue 200 times per second, and adjusts voltage and current accordingly to maintain appropriate power. This unique capability differentiates Instant Response generators by their high power efficiency rating (PER). That's smart generator technology.

PER indicates the ability of a generator to accurately deliver the selected power into a wide range of tissue types. With a PER of 97, the Force EZ generator provides a consistent surgical effect.

Instant Response technology provides consistent power through different tissue types.

The Force EZ generator provides surgeons with the advantage of accurately delivering the selected power setting, even through resistant tissue. The power curve below illustrates the Force EZ generator's consistent output.

When a conventional generator encounters tissue changes, both power delivery and cutting efficiency are reduced. This means that higher power settings are required in order to cut through all types of tissue. With higher power setting, more energy is delivered and tissue damaging increases.

Features

  • Instant Response technology ensures that the power delivered remains virtually constant, regardless of the tissue type
  • Improved performance at lower power settings minimizes the risk of tissue damage and neuromuscular stimulation
  • Three internal microcontrollers reduce system reaction time and increase the system's processing speed
  • Easy to use, cost effective system when performance is required and price is of equal concern
  • Two cut modes, both controlled by Instant Response technology, offer surgeons a variety of choices:
    • Pure Cut for a clean, precise cut
    • Blend for cutting with hemostatsis
  • Two primary coag modes:
    • Low for lower voltage contact coagulation suitable in laparoscopic and delicate tissue work
    • High for efficient noncontact coagulation in most applications
  • Standard bipolar mode:
    • Standard mode is controlled by Instant Response technology and utilizes low voltage to prevent sparking
  • Versatile system that is uniquely compatible with other devices, including:
    • Force Argon IITM and Force GSU argon coagulation system
    • OptiMummTM smoke evacuator, through a direct cable link
  • A Power Efficiency Rating (PER) of approximately 97 for accurate and consistent cut performance
  • Separate monopolar and bipolar footswitch connectors on rear panel for easy set up
  • Convenient design for boom applications:
    • Additional front mounted footswitch connector is switchable, allowing monopolar or bipolar activation by a monopolar footswitch

Specifications

Physical Weight & Dimensions

  • Height: 5 inches (12.7 cm)
  • Width: 16 inches (40.6 cm)
  • Length: 15.6 inches (39.5 cm)
  • Weight: less than 15 lbs (6.8 kg)
  •  

Output Waveforms

  • Bipolar: 470 kHz sinusoid
  • Monopolar Cut:
    • Pure: 393 kHz sinusoid
    • Blend: 393 kHz bursts of sinusoid, recurring at 27 kHz intervals. 50% duty cycle envelope
  • Monopolar Coag:
    • Desiccation:
    • Low 1: 240 ± 40 kHz sinusoid recurring at 39 kHz. 8% duty cycle
    • Low 2: 393 kHz sinusoid
    • Low 3: 393 kHz sinusoid
    • Fulguration:
    • High 1: 470 ± 40 kHz damped sinusoidal bursts with a repetition frequency of 57 kHz
    • High 2: 470 ± 40 kHz damped sinusoidal bursts with a repetition frequency of 30 kHz
  • Output power changes by less than 15% or 5 watts, whichever is greater, as the line voltage varies from 90-135 volts (into a 300 ohm load).
  •  

Low Frequency Leakage (50-60 Hz)

  • Source current, patient leads, all outputs tied together.
  • Normal polarity, intact chassis ground: < 10µA
  • Normal polarity, ground open: < 50µA
  • Reverse polarity, ground open: < 50µA
  • Sink current, 140V applied, all inputs: < 50µA
  •  

Power Readouts

  • Agree with actual power into rated load to within ± 15% or 5 watts, whichever is greater. Dosage error monitor.
  •  

PER = 97

  • PER (Power Efficiency Rating) is the measure of an electrosurgical generator's ability to accurately deliver the selected power into a wide range of tissue types.
  •  

Input Power Requirements

  • 110-120Vac:
    • Operating Range: 85-140Vac
    • Max Current Cut: 8A
    • Max Current Coag: 4.2A
  • 220-240Vac:
    • Operating Range: 170-280Vac
    • Max Current Cut: 4A
    • Max Current Coag: 2.1A
  •  

High Frequency Leakage

  • Bipolar: Less than 60 mArms
  • Monopolar: Less than 150 mArms
  •  

REM™ Contact Quality Monitoring System

  • Measurement Frequency: 80 kHz ± 10 kHz
  • Measurement Current: Less than 10 µA
  • Acceptable Resistance Ranges:
    • REM pad – 5-135 ohms
    • Non-REM pad – less than 20 ohms
    • Acceptance range is 5-135 ohms after REM PolyHesive II return electrode is applied
  • Adaptive REM: REM trip is baseline impedance plus 40%. For example, if the baseline impedance is 30 ohms, the upper level trip is approximately 42 ohms. If the pad-patient impedance falls below the baseline impedance, a new baseline is established.
  •  

Output Characteristics

  • Bipolar – Standard Mode:
    • Maximum P-P Voltage: 300
    • Rated Load (OHMS): 100
    • Maximum Power (Watts): 70
    • Crest Factor (Typical): 1.5
  • Monopolar Cut – Pure Mode:
    • Maximum P-P Voltage: 2000
    • Rated Load (OHMS): 300
    • Maximum Power (Watts): 300
    • Crest Factor (Typical): 1.5
  • Monopolar Cut – Blend Mode:
    • Maximum P-P Voltage: 3400
    • Rated Load (OHMS): 300
    • Maximum Power (Watts): 200
    • Crest Factor (Typical): 2.1
  • Monopolar Coag – Desiccate Low 1 Mode:
    • Maximum P-P Voltage: 3500
    • Rated Load (OHMS): 500
    • Maximum Power (Watts): 120
    • Crest Factor (Typical): 5.0
  • Monopolar Coag – Desiccate Low 2 Mode:
    • Maximum P-P Voltage: 660
    • Rated Load (OHMS): 300
    • Maximum Power (Watts): 120
    • Crest Factor (Typical): 1.5
  • Monopolar Coag – Desiccate Low 3 Mode:
    • Maximum P-P Voltage: 1100
    • Rated Load (OHMS): 300
    • Maximum Power (Watts): 120
    • Crest Factor (Typical): 1.5
  • Monopolar Coag – Fulgurate High 1 Mode:
    • Maximum P-P Voltage: 6200
    • Rated Load (OHMS): 500
    • Maximum Power (Watts): 120
    • Crest Factor (Typical): 5.0
  • Monopolar Coag – Fulgurate High 2 Mode:
    • Maximum P-P Voltage: 8500
    • Rated Load (OHMS): 500
    • Maximum Power (Watts): 120
    • Crest Factor (Typical): 7.0
6

Accessories & Supplies

Price

Reusable Grounding Plate Cord 2 Pin Plug: For Reusable Dispersive Electrode Plates

P00892

Web ID: 1559
Price

Reusable Dispersive Electrode (Grounding Pad)

<span>$</span>0<sup>.00</sup>

P00893

Web ID: 404
Price

Reusable Dispersive Electrode (Grounding Pad)

P00893

Web ID: 403
Price

ESU / Electrosurgical Switch Pens - 1 Pen

P00507

Web ID: 1543
Price

Bovie ESPR2 Pencil

P01147

Web ID: 12458
Price

Standard

P02013

Web ID: 11258
Price

Angled

P02011

Web ID: 11259
Price

Extended

P02012

Web ID: 11260
Price

Standard

P02085

Web ID: 11266
Price

Universal Valleylab Cart

P01594

Web ID: 13843
Price

Bipolar Foot Pedal for Valleylab Units

P99002

Web ID: 13846
Price

Monopolar Footpedal for Valleylab Units

P99001

Web ID: 13845
Price

Power Cord

P00100

Web ID: 12845

Catalog

Help & Settings

Equipment

See all

Supplies

See all