Vet-Dop 2 Doppler Blood Pressure System

Vmed

Vet-Dop 2 Doppler Blood Pressure System

Web ID: 12374
Product Number: 70904

Need help choosing?

Speak to one of our expertly trained specialists!

Need help Financing?

Check out financing options from OnePlace Capital.

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The Vet-Dop2 is designed for veterinarians to listen to arterial and venous blood flow audio in small animals.

When used with a sphygmomanometer and an animal blood pressure cuff of the correct size, systolic
blood pressure can be determined. The Vet-Dop2 works well on all small animals as well as exotics.

Features:

  • Six animal cuffs with size gauge
  • Certified sphygmomanometer
  • Six probe attachment straps for long-term monitoring
  • Stereo audio headphones
  • Doppler procedure and hypertension video
  • Storage pouch
  • Protective carrying pouch
  • Charger for 100-240 volts, 50/60 Hz.
  • 9.6 MHz Doppler probe with attachment straps
  • Instructional DVD

Product Testimonials:

...the systolic blood pressure readings were virtually identical between the three units, however the Vet-Dop was much more sensitive in detecting arterial blood flow. This means that the blood pressure determinations were performed more rapidly and more consistently using the Vet-Dop. It is my opinion that the Vet-Dop is a significant improvement in obtaining systolic blood pressure readings compared to the other Doppler equipment that I used in this trial.

— Gary Norsworthy
DVM, Diplomate, American Board of Veterinary Practitioners (Feline Specialty), Alamo Feline Health Center

Specifications

  • Type: CW ultrasonic Doppler blood flow detector
  • Ultrasound Frequency: 9.6 Mhz
  • Construction: High impact ABS-PC
  • Dimensions (Overall): 6" x 4.625" x 1.75"
  • Weight: 15 oz.
  • Doppler Frequency: 9.6 MHz
  • Audio Output: Speaker and headset jack with speaker?cutoff
  • Power Adaptor: Input: 110/220 VAC 50 or 60 Hz.
  • Output: 5 VDC (Will not operate with AC connected)
  • Battery: Rechargeable Lithium-ion
  • Battery Use Between Charges: 35-40 hours continuous
  • Transducer: Focused piezoelectric elements with 5 Ft.Cable
  • Transducer Dimensions: 0.6" X 0.5" X 0.24"
  • Connector: 5 Pin circular DIN
  • Sphygmomanometer: 0-300 mmHg certified manometer?with bulb type pump and deflation valve.
  • Headphones: Stereo audio with 3.5 mm phone plug
  • Cuffs: 6 ea. for limb circumferences 3.3-16.8 cm
0