A refurbished Siemens 300A Servo Ventilator offers a wide range of ventilation modes together with an Automode function for greater treatment possibilities, shorter weaning times and increased patient comfort.

Features:

  • Servo ventilator
  • Automode for fully adaptive patient interaction
  • Neonate to adult patient range
  • Wide range of ventilation modes: Controlled, Supported, Combined
  • Easy to use
  • Refurbished

Available Accessories For Product

  • Carts
  • Breathing Systems
  • Compressors
  • External Power Supply
  • Humidifiers

Specifications

Dimensions:

  • Patient unit: 9.5"w x 14.6"d x 9.4"h
    User interface: 17.0"w x 15.9"d x 12.8"h

Weight: Approx.52.9 lbs

Ventilation Modes:

  • Controlled
  • Supported
  • Combined

Patient Range:

  • Adult/Pediatric/Neonate

Classification:

  • IEC60601-1/EN60 601-1 Type B

Method of Triggering:

  • Flow and Pressure

Flow Range: 0.1 ml/s - 3 l/s

Power Supply: 100, 120, 220, and 240 VAC 10%, 50-60Hz

Alarms:

  • Airway Pressure (Upper): 15-120 cm H2O
  • High Continuous Pressure: Set PEEP-level +15 cm H2O for more than 15 seconds.
  • O2 concentration: Set value 6%. Lower alarm limit cannot go below 18% or exceed 90%.
  • Expired Minute Volume (Upper Alarm Limit): Adult/Pediatric Range: 0-60 l/min, Neonate Range: 0-6 l/min.
  • Expired Minute Volume (Lower Alarm Limit): Adult/Pediatric Range: 0.3-40 l/min, Neonate Range: 0.06-4 l/min.
  • Apnea: Adult: 20 s. Pediatric: 15 s. Neonates: 10 s.

Monitoring:

  • Frequency: CMV or SIMV frequency 1% or 0.5 b/min.
  • Pressures: Peak, Pause, Mean and End exp. 5% b/min or 2 cm H2O
  • Insp. Tidal Volume: Adult Range: 50-3999 ml 6% or 3 ml. Pediatric Range: 10-399 ml 6% or 0.5 ml. Neonate Range: 2.0-39 ml 6% or 0.5 ml.
  • Exp. Tidal Volume: Adult Range: 50-3999 ml 6% or 3 ml. Pediatric Range: 10-399 ml 6% or 0.5 ml. Neonate Range: 2.0-39 ml 6% or 0.5 ml.
  • Exp. Minute Volume: Adult Range: 4.0-60 l/min 6% or 0.1 l/min. Pediatric Range: 1.0-5.0 l/min 6% or 0.05 l/min. Neonate Range: 0.20-1.50 l/min 6% or 0.02 l/min.
  • Flow Rate: 0.00-3.00 l/s or 0.00-180 l/min 1% or 1% or 1 digit.
  • O2 Concentration: 5% of read value