The SciCan Statim 5000 cassette autoclave (or steam sterilizer) uses a steam injector system provides temperature consistency and expels the air which causes oxidation. This process is effective on hollow and solid instruments. The Statim 5000 has a 9-minute complete sterilization cycle. Key pad operation and display screen gives users an easy interface. This product, and other SciCan autoclaves are available new from DRE.

Features

  • Fast, Compact, Reliable
  • Effective Every Time
  • Gentle on Instruments
  • Easy to Use and Maintain

Statim 5000 with optional built in printer - #785000B

  • Type: Thermal printer
  • Print: 20 characters per line
  • Speed: 1 line/sec.
  • Capacity: 80 cycles/roll

Optional SciCan Surgical Plastic Serilization Trays for Statim 5000 Sterilizers

4600A | Small Single 4.0" x 6.5" x 0.75"

  • Holds 6

6100A | Large Single 6.0" x 10.0" x 0.75"

  • Holds 2

6120A | Large Double Stack 6.0" x 10.0" x 1.50"

  • Holds 2

Specifications

Unit Size:

  • L 55.5 cm x W 41.5cm x H 19cm | L 21.75" x W 16.25" x H 7.5"
  • Weight Without Water: 30kg / 66lbs

Cassette Internal Dimensions:

  • L 38cm x W 18 cm x H 7.5 cm | L 15" x W 7" x H 3"

Power Consumption:

  • 110-120V 60Hz, 11A, 1300 W
  • In EU 220-240V, 50Hz, 6A
  • In Japan 100V 50/60Hz, 11A

Reservoir Capacity:

  • 4.0 litres (distilled water)
  • Approximately 18 cycles

STATIM 5000: USA | *Cycle time is dependent on instrument load

  • Sterilization Time Unwrapped: 3.5 minutes
  • Sterilization Time Wrapped: 6 minutes
  • Sterilization Time Rubber/Plastic: 35 minutes
  • Sterilization Time Heavy Duty Unrwapped/Air Drying: 6 minutes
  • Sterilization Temp: 132 C
  • Sterilization Temp: 132 C
  • Sterilization Temp: 121 C
  • Sterilization Temp Heavy Duty Unwrapped/Air Drying: 132 C
  • Total Cycle Time Unwrapped: 9 minutes
  • Total Cycle Time Wrapped: 17.5 minutes
  • Total Cycle Time Rubber/Plastic: 45 minutes
  • Total Cycle Time Heavy Duty Unwrapped/Air Drying: 12 minutes

Warranty

  • 1 year (Parts and Labor)