The Hallowell Model 2002 Pro Anesthesia Ventilator is an electronically controlled, time-cycled, pressure limited ventilator.

Electronic control

Eliminates the substantial driving gas required to operate pneumatically controlled ventilators.

Time cycled

Ensures consistently spaced breaths. The possibility of stacking breaths or auto-PEEP is eliminated by keeping the I:E ratio constant at 1:2. This means that regardless of the respiratory rate, setting two-thirds of the breath will remain for expiration. The respiratory rate is adjustable from 6 - 40 breaths per minute (BPM).

Volume constant

Ensures that each delivered breath will have essentially the same volume, independent of changes in patient compliance and airway resistance. The deliverable tidal volume (TV) range is from approximately 20 cc to 3,000 cc.

Pressure Limited

Provides for patient safety by limiting the maximum working pressure (MWPL) to a user adjustable pressure range of 10 - 60 cm H2O.

Features

  • Electronically controlled ventilator.
  • Time-cycled operation ensures consistent breath spacing, helping to eliminate the possibility of stacking breaths.
  • Low gas alarm indicates low gas supply or problems with the gas connections.
  • Volume control knob divides 100 liters/minute of drive gas into 9.5 turns of the valve, allowing operators to make precise adjustments.
  • Respiratory rate adjusts from 6 to 40 breaths per minute (BPM).
  • Constant volume delivery for consistent operation, independent of changes in patient compliance and airway resistance.
  • Pressure limiting capabilities with an adjustable pressure range of 10 - 60 cm H2O.

Specifications

Operational Characteristics

  • Rate: 6-40 bpm
  • Tidal Volume: 0-3000 ml
  • I:E Ratio: 1:2 (preset)
  • Gas Supply: Oxygen or Clean Dry Air
  • Pressure & Flow: 35-65 psi @ 3 scfm (2.4 - 4.4 bar @ 100 lpm)

Controls

  • Rate: Linear, 6-40 bpm w/Power Switch
  • Volume: 9-turn Fine metering valve
  • Maximum Working Pressure Limit: Linearly Adjustable, 10 - 60 cm H2O

Indicators

  • Power On: Front Panel-mounted green LED
  • Alarm, Visual: Front Panel-mounted yellow LED
  • Alarm, Audio: Internal audio transducer

Physical

  • Unit Weight: Approximately 13 lb. (5.9 kg)
  • Controller Footprint: 9"W x 10"D (228 W x 254 D mm)
  • Configuration Overall Height:
  • 300 ml: 12 3/4"
  • 1600 ml: 12"
  • 3000 ml: 17 1/4"
  • Power Requirements: 105-125 or 208-240 vac, 50-60 Hz
2

Accessories & Supplies

Anesthesia Ventilators

View all

Bellows and Housings

View all

Bellows Adapter, 0-300ml

72000B

Web ID: 1174

Bellows Housing (300-1600ml)

72001BH

Web ID: 1177

Bellows (300-1600ml)

72001AB

Web ID: 1178

Bellows Housing (0-300ml)

72000BH

Web ID: 1175

0-300ml Attachment

72000BA

Web ID: 1172

Bellows (0-300ml)

72000PB

Web ID: 1173

Catalog

Programs & Features

Help & Settings

Equipment

See all

Supplies

See all