DRE Digital 200 12 Megapixel Digital Navigator

DRE

DRE Digital 200 12 Megapixel Digital Navigator

Web ID: 11152
Condition: Retired

Need help choosing?

Speak to one of our expertly trained specialists!

Need help Financing?

Check out financing options from OnePlace Capital.

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

High x-ray imaging performance at an affordable price

The DRE Digital 200 12 Megapixel Digital Navigator uses a very stable detector compared with CR and flat panel detectors and provides high-quality images for all diagnostic purposes. The detector allows the user to effectively adjust the brightness and contrast for a precise, clear image every time.

Features

  • Includes: imaging unit, work station computer, imaging software, printer, x-ray generator, float top table, x-ray tube.
  • Excellent dynamic range with 16-bit digitization.
  • Complementary metal oxide semiconductor technology.
  • Efficient design for a high throughput in radiography exams.
  • Specially-dedicated optics for high spatial resolution.
  • Stable operation for years of use.
  • Five year warranty.

 

Components

DRE Digital 200 Flat Panel

  • Elimination of film processing for less-expensive operation.
  • No odors or hazardous waste materials.
  • Faster, image display.
  • Decrease of patient x-ray retakes in some cases.
  • Image manipulation for and enhanced diagnosis.
  • Better reliability for consistent high-quality images.
  • Digital images can be shared via email.
  • Archival, long-term storage and retrieval capabilities.
  • Approximately 20,000 images are stored.
  • A comprehensive toolkit permits physicians to adjust image gray scale window/level, ensuring confidence in their assessments.
  • Transmits images using the DICOM format and protocol to any DICOM-based archiving system.

 

DR Navigator Software

  • Comprehensive image processing by optimal tissue equalization, image sharpening and brightness adjustment.
  • Image process parameters are selectable to maximize the preset algorithms.
  • Full size image display within 10-20 seconds.
  • DICOM 3.0 standard.
  • Preview function.

 

Superior High-Frequency X-Ray Generator

  • Superior performance, real-time monitoring self-diagnosis and error code display.
  • Tube anode HU display & protection, overload & housing overheat protection.
  • Self-calibration function.

Specifications

Digital Imaging Unit - Mounted in Table Base

  • Dimensions: 18 3/4”W x 15 3/4”D x 19”H
  • Weight: 43 pounds
  • DR1417-6G DRvwt Imaging System with 300,000 shutter exposure life expectancy
  • Imaging Media: DOUBLE SPEED Rare Earth green Phosphor Scintillate Plate
  • 14X17 Image size, 12 mega pixel, 65,536 shades of gray, Full Frame Transfer 16 Bit
  • Includes: Power Cord, Computer Imaging System Interconnection Connector Cables

X-Ray Generator

  • kW Rating........................................40kW
  • kVp Range........................................40 to 125 kVp, 1kV step
  • Time Range......................................0.001 to 10 sec.
  • mA Range........................................10 to 500mA
  • HV Cable..........................................8 meters
  • kVp Accuracy.....................................<(1% + 1kV)
  • mAs Accuracy....................................<(3% + 0.01 mAs)
  • Generator Mounter............................Provided
  • Line Normal Phase..................... 240V AC, 1, 60Hz @ 70 Amps

X-Ray Tube Assembly

  • Model / Maker..................................Toshiba
  • Target Angle....................................16 Degrees
  • Focal Spot Size.................................6 / 1.2 mm
  • Max. Tube Voltage............................125kV
  • Max. Anode HU.................................140 kHU (100kJ)

X-Ray Collimator

  • Control............................................Manual, 30 sec. timer
  • Field Shape......................................Rectangular
  • Max. Field Size.................................>43 x 43 cm / 100 cm SID
  • Max. kV Shield.................................150 kV
  • Lamp..............................................Quartz Halogen 160 Lux

Digital Image Receptor 

  • Active Matrix Size..............................14” x 17” (35 x 43 cm)
  • Image Matrix....................................12 Megapixels
  • Image Resolution..............................Exceeds FDA’s Human Radiology Resolution Standard
  • Acquisition Time................................10 - 20 Seconds
  • Dynamic Range.................................16-bit Grayscale, 65,000 Shades of Gray
  • File Format........................................DICOM

Tube Stand & Float Top Table

  • SID .................................................Variable 12” - 40”
  • Grid .................................................200 lpi (ratio 10:1)
  • Table Top Size...................................30” x 64”
  • Tabletop Movement............................4 - way
  • Tabletop Stroke (longitudinal)..............12” (5”)
  • Tabletop Stroke (lateral)......................8” (4”)
  • Dimension.........................................32”(H) x 42”(W) x 40”(D)
  • Weight...............................................80kg (176 lb)