Technical Specifications
Non-Invasive Blood Pressure (NIBP) - Patented Colin Technology
- Measurement technology Oscillometric method
- Measurement method Linear deflation method
- Pressure display range 10 to 300mmHg
- Pressure display accuracy Less than ±3mmHg
- NIBP Measurement range
- Adult/pediatric mode
SYS 60 to 250mmHg
MAP 45 to 235mmHg
DIA 40 to 200mmHg
Pulse rate 40 to 200bpm
SYS 40 to 120mmHg
MAP 30 to 100mmHg
DIA 20 to 90mmHg
- Pulse rate 40 to 240bpm
- NIBP accuracy AAMI SP-10:2002+A1:2003
- Pulse rate accuracy ±2% or ±2 beats
ECG (Electrocardiogram)
- Leads 3/5 Lead
- Lead I, II, III, aVR, aVL, aVF, V (Chest Lead)
- Heart Rate
- Measurement Range 20 to 250bpm
- Accuracy ±3bpm or ±5% (whichever is greater)
Respiration (im RR)
- Measurement method Trans-thoracic impedance
- Leads RA to LA
- Range 0, 3 to 120breaths/min
- Accuracy ±3 breaths/min
SpO2 (Pulse oximeter)
- Measurement method 2 wave length pulse wave type
- Range 1 to 100% SpO2
- Accuracy Adult/pediatric (When using SpO2 Disposable Sensor MAX-A) 70 to 100% SpO2 ±2 digits, 1 to 69% SpO2 unspecified
- Pulse Rate Range 20 to 250bpm
- Pulse Rate Accuracy ±3bpm
- Display update Less than 30 sec
Temperature Measurement (Option)
- Measurement method Thermistor
- Probe Type Thermistor probe YSI 400 series (2 channels) (Probes not included)
- Range 15 to 45°C (59 to 113°F)
- Display Accuracy ±0.1°C (25 to 45°C) (77 to 113°F) ±0.2°C (15 to less than 25°C) (59 to less than 77°F)
- Probe Accuracy ±0.1°C (±0.18°F)
IBP (Option)
- Measurement Method: Pressure Transducer Method
- Pressure Measurement Range - -50 to +300mmHG
- Pulse Rate Measurement Range – 20 to 250bpm
- Display Accuracy - ±3mmHG
- Standard – IEC60601-2-34:2000
CO2 (Option)
- Measurement method Non-dispersive Infrared Spectroscopy
- Range 0-100mmHg : 0-13.3kpa : 0-10%CO2
- Accuracy ±2mmHg or ±4% (whichever is greater)
- Respiration (awRR) Range 0 to 120 breaths/min
- Respiration (awRR) Accuracy ±1 breath/min
Recorder (Option)
- Type Thermal
- Weight 150g (0.33lbs)
- Resolution 8 dot/mm
- Number of channels 1 to 2 channels
- Paper Type Thermal
- Paper Width 50mm (2in)
- Paper Speeds 25.0mm/sec and 50.0mm/sec (1in/sec and 2in/sec)
General
- Dimensions 360(W) x 215(D) x 280(H)mm (14.2 x 8.5 x 11in)
- Weight 5.5kg (12.1lbs) (excluding optional configurations and accessories)
- Display - Screen Size 26.4cm (10.4in) measured diagonally, Screen Type/Color Liquid Crystal Display (LCD) color, Resolution 800 x 600 pixels
- Number of traces 4 or 6 waveforms
- Safety Standard IEC60601-1:1988+A1:1991+A2:1995
- Degree of protection (enclosures) IP21
- Type of protection Type CF - Applied part
Power Requirement
- AC Power 100-240V~50/60Hz, 0.5-1.3A
- Battery Ni-MH, 12V/3.8Ah (1 included)
Environmental
- Operating Temperature 10 to 40°C (50 to 104°F)
- Storage Temperature -20 to 60°C (-4 to 140°F)
- Operating Humidity 15 to 90% RH, non-condensing
Accessories
Most models: Reusable adult cuff, adult 3.5m cuff hose, ECG cable,
ECG 3-lead wires, SpO2 Durasensor® DS-100A, SpO2 extension cable
DOC-10, operation manual, power cord, rechargeable battery (1).
Available with: CO2 sampling set, printer paper, ECG 5-lead wires,
temperature probes, rolling stand, and a full size range of reusable and
disposable BP cuffs