User-friendly touch-screen patient monitor — Now with Masimo SET® Pulse Oximetry!

Features

  • ST segment monitoring and 72 hours trend data analysis
  • Built-in battery
  • Masimo SET® Pulse Oximetry — ask your Avante representative for details
  • NIBP list and OxyCRG dynamic view display
  • Drug dose calculations
  • Large font display with 4, 6 and 8 waveforms shown
  • Built-in thermal recorder
  • Networkable with a central monitoring system via a wireless or wired network
  • Compact design convenient for mobile monitoring
  • Multi-lingual settings
  • Includes veterinary accessories for parameters ordered

Each monitor will automatically include the CO2 and IBP ports. These parameters are listed as options and are NOT standard. Your veterinary or research facility has the ability to upgrade to any of these parameters at a later time without having to send the monitor into DRE! Call a Avante Account Manager for further details.

Specifications

Physical Dimensions

  • 11" H x 12.6" W x 6.2" D
  • Weight - 11bs (5kg)

Application

  • Veterinary patients

Power

  • Power Source - External AC power or internal battery
  • AC Power - 100-240VAC, 50/60Hz, <150VA
  • Battery - Rechargeable Lead-Acid; Operating time under the normal condition (1 hour)
  • Operating time after the first alarm of low battery (10 min.)

Environmental

  • Working Temperature: 5-40 C
  • Storage Temperature: 0-65 C
  • Working Humidity: 30-75%
  • Storage Temeprature: ≤80%
  • Operating Altitude: Up to 5,000 meters
  • Hyperbaric Pressure - Up to 405.3 kPa

Performance Specifications

  • Display - 12.1” color TFT, Touch Screen
  • Resolution - 800 x 600 pixels
  • Trace - 4, 6 or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2
  • Indicator - Alarm indicator; Power indicator QRS beep and alarm sound
  • Trend Time - 72 hours
  • Recorder - Built-in, thermal array, 2 channels
  • Record - Width 48mm
  • Recorder - Paper 50mm
  • Record - Speed 25mm/s, 50mm/s
  • OxyCRG - Combines HR, SpO2, and resp. trends into a single graph ECG
  • Input - 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice - I, II, III, aVR, aVF, aVL, V
  • Gain Choice - x0.125, x0.25, x0.5, x1.0, x2.0

Filter

  • Diagnostic mode - 0.05 – 100Hz
  • Monitoring mode - 0.05 – 75Hz
  • Surgical mode - 1 – 20Hz
  • Frequency Characteristic - 0.05-40 Hz
  • ECG Waveforms - 7 channels
  • Penetration Voltage - 4000VAC 50/60Hz
  • Sweep Speed - 12.5, 25 and 50 mm/s
  • HR Display Range - 30-300bpm
  • Accuracy - 1% or 1bpm, whichever is greater
  • S-7 Segment Detection - 7 channels
  • Measurement Range - -2.0mv – +2.0mv
  • Arrhythmia Analysis - 13 types
  • Alarm Limit Range Setting - Upper limit 80-400bpm; Lower limit 20-150bpm

RESP

  • Measure Method - RA-LL impedance
  • Range - 0-120 rpm
  • Accuracy - + 3 rpm
  • Alarm Upper-lower Limit Setting - Upper limit 6-120 rpm, Lower limit 3-120 rpm
  • Sweep Speed - 12.5 and 25 mm/s

NIBP

  • Measuring Technology - Automatic oscillating measurement
  • Cuff Inflating - <30s (0 – 300mmHg, standard adult cuff
  • Measuring Period - AVE<40s
  • Mode - Manual, Auto, STAT
  • Measuring Interval in AUTO Mode - 2 min-4 hrs
  • Pulse Rate Range - 30-250 (bpm)
  • Measuring Range - Adult/Pediatric Mode, SYS 40-250 (mmHg), DIA 15-200 (mmHg); Neonatal Mode, SYS 40-135 (mmHg), DIA 15-100 (mmHg)
  • Resolution - 1mmHg
  • Accuracy - Pressure, Maximum Mean error 5mmHg, Max. Standard deviation 8mmHg
  • Overpressure Protection - Adult Mode 280(mmHg), Neonatal Mode 150 (mmHg)
  • Alarm Limit Setting - SYS 50-240 mmHg, DIA 15-180 mmHg

TEMP

  • Range - 0 – 50 C (32 – 122 F)
  • Accuracy - Without sensor
  • Display Resolution - 0.1 C
  • Alarm Upper-lower Limit Setting - Upper limit 0-50 C, Lower limit 0-50 C
  • Channel - 2 channels, provide T1, T2, ΔT
  • Alarm Limit Setting - 10-50 C

Masimo SET SpO2

  • Measuring Range:
    • SpO2: 1~100 %
    • PR: 25~20 %
  • SpO2 Accuracy (non-motion):
    • Adult Pediatric: 70~69%: unspecified
    • Neonate: 70~69 %: unspecified
  • SpO2 Accuracy (motion):
    • Adult Pediatric: 70~69% : unspecified
    • Neonate: 70~69 % : unspecified
  • PR Accuracy (non-motion):
    • Adult Pediatric Neonate: 25?240 bpm: ±3 bpm
  • PR Accuracy (motion):
    • Adult Pediatric Neonate: 25~240 bpm: ±5 bpm
  • Low Perfusion Performance: >0.02 % Pulse Amplitude and % Transmission >5
    • SpO2: ±2 %
    • PR: ±3 bpm
  • Modes:
    • Averaging mode: 2,4,8,10,12,14 and 16 s
    • Sensitivity: Normal, APOD and Maximum

IBP (Option)

  • Measurement Range - -10-300mmHg
  • Channel - 2 channels
  • Pressure Transducer Sensitivity, 5μV/V/mmHg
  • Impedance Range - 300-3000Ω
  • Transducer Sites - ART, PA, CVP, RAP, LAP, ICP
  • Resolution - 1mmHg
  • Accuracy - 1mmHg or 2%, whichever is greater
  • Alarm range - -10-300mmHg

EtCO2 (Option) (Respironics)

  • Mode of Sampling - Sidestream
  • Principle of Operation -Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
  • CO2 Measurement Range - 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
  • CO2 Calculation Method - BTPS (Body Temperature Pressure Saturated)
  • CO2 Resolution - 0.1mmHg(0-69mmHg); 0.25mmHg(70-150mmHg)
  • CO2 Accuracy - 0-40 mmHg 2 mmHg; 41-70 mmHg 5% of reading; 71-100 mmHg 8% of reading; 101-150 mmHg 10% of reading; Above 80 breath per minute 12% of reading
  • Sampling Rate - 100Hz
  • Respiration Rate - 2-150 bpm
  • Respiration Rate Accuracy - 1 breath
  • Response Time - <3 seconds - includes transport time and rise time
  • Inspired CO2 Measurement Range - 3-50 mmHg

Accessories & Supplies

Replaceable Veterinary Alligator Clip Compatible with Waveline

Web ID: 9892

Large Ear Clip for Vet Use: Qty: 1

Web ID: 1024

Small Ear Clip for Vet Use: Qty 1

Web ID: 1025

Alligator Clips for ECG Lead Wires - Set of 5

P00943.5 = 1 alligator clip. When adding to order, use quantity of 5, $2.06 each

Web ID: 481

ECG Snap to Banana Plug Adapter - Pack of 10

P01222

Web ID: 829

Masimo M-LCNS 10FT Patient Cable for the Waveline Series Monitors

P05125 (10 ft.) P05125-4D (4 ft.) - 8/10/2020 being replaced by Red Diamond technology: PN 4104 is the 10ft cable #P05125RDC and the lingual tip Red Diamond is #4053 #P05125RDLS

Web ID: 12880

Masimo M-LCNS 4FT Patient Cable for the Waveline Series Monitors

P05125-4 4ft; P05125 10ft

Web ID: 12634

Masimo Reusable Animal Clip Sensor

P05125LS - being replaced by Red Diamond technology: PN 4104 is the 10ft cable #P05125RDC and the lingual tip Red Diamond is #4053 #P05125RDLS

Web ID: 12606

Masimo Reusable Animal Multisite Sensor

Web ID: 12607

Masimo Reusable Animal Transflectance Sensor

P05125RDTS

Web ID: 12608

Nellcor V-Sat | Y-Site SpO2 Vet Probe: 9 Pin

80033V

Web ID: 1506

5 Pin Digital SPO2 Cable for Waveline EZ, Touch and Pro

Web ID: 9888

Power Cord

P00100

Web ID: 12845

Battery for Waveline Touch

P00289

Web ID: 9895

Recording Paper for Waveline Series Monitors

P01620

Web ID: 12288

Waveline Wall Mount Bracket

P02116

Web ID: 12923

Mounting Plate for Waveline Series

Web ID: 12906

Waveline Rolling Monitor Stand

Web ID: 10586

Catalog

Programs & Features

Help & Settings

Equipment

See all

Supplies

See all