EU Cookie Consent

We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read our Privacy Policy

Avante Echo CO2 Capnograph Monitor

Avante

Avante Echo CO2 Capnograph Monitor

Web ID: 10606
Product Number: 60129CO2RS

Need help choosing?

Speak to one of our expertly trained specialists!

Need help Financing?

Check out financing options from OnePlace Capital.

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The Avante Echo CO2 provides cost-effective SPO2 and CO2 monitoring with accuracy and durability.

The Echo CO2 ensures effective capnography monitoring for intubated and non-intubated patients for continuous long term monitoring. It is tailored for mechanically ventilated and non-intubated patients.

Features:

  • 5.7 inch high resolution display for easy reading
  • Lightweight, portable design and user-friendly interface for easy operation
  • Flexible configurations to meet different clinical needs
  • Standard SpO2
  • PR measurement
  • Respironics Loflo sidestream and CAPNOSTAT 5
  • ETCO2 mainstream measurement
  • Real-time parameters measurement display with trend table for easy reviewing
  • Built-in rechargeable Lithium-ion battery for
  • 10 hours continuous working
  • Powerful storage capacity
  • Bi-directional communications with central station by wired or wireless network
  • Nurse call

Specifications

Physical Specifications

  • Size: 200.8mm (L) x 241mm (H) x 189 mm (D)
  • Weight: 3 kg
  • Display: 5.7 inches
  • Color TFT resolution: 640X480
  • Power Supply: 100-240 VAC, 50/60HZ
  • Pmax=70VA FUSE T 1.6AL
  • Battery Type: Lithium-ion
  • Voltage: 14.8 V DC Capacitance: 4,400 mAh
  • Working period: Color TFT 480min
  • Rechargeable period: < 360min
  • Thermal Recorder: (Optional)
  • Record Width: 48 mm
  • Paper Speed: 25mm/s

SpO2

  • Measuring Range: 0 ~ 100 %
  • Alarm Range: 0 ~ 100 %
  • Resolution: 1 %
  • Accuracy
  • Adult (including Pediatric)
  • 2% (70%~100% SpO2)
  • Undefined 0~70% SpO2

Neonate

  • 3% (70%~100% SpO2)
  • Undefined (0~70% SpO2)

Pulse Rate

  • Measuring and Alarm Range: 30 ~ 300bpm
  • Resolution: 1bpm
  • Accuracy: 3bpm
  • Data update period: 2s
  • ISO 9919
  • Respironics CO2

Mainstream

  • CO2 Measurement Range
    • 0 to 150 mm Hg,0 to 19.7%,
    • 0 to 20 kPa (at 760 mm Hg)
  • Rise Time
    • Less than 60 ms Adult/Infant
    • Reusable or Single Patient Use
  • Airway Adapter
  • CO2 Resolution
    • 0.1 mm Hg -- 0 to 69 mm Hg
    • 0.25 mm Hg -- 70 to 150 mm Hg
  • CO2 Accuracy
    • 0-40 mm Hg -- 2 mmHg
    • 41 - 70 mm Hg -- 5% of reading
    • 71 - 100 mm Hg -- 8% of reading
    • 101 - 150 mm Hg -- 10% of reading
    • Above 80 bpm -- 12% of reading
  • CO2 Stability
  • Short Term Drift: Drift over four hours shall not exceed 0.8 mm Hg max.
  • Long Term Drift: Accuracy specification will will be maintained over a 120-hour period
  • Respiration Rate Accuracy
    • 1 breath
    • Calibration
  • No routine user calibration required. An airway adapter zero is required when changing to a different style of airway adapter
  • Water Resistance
    • IPX4-Splash-proof (sensor head only)
    • Shock Impact
    • EN60068-2-6 Sinusoidal Vibration
    • EN60068-2-27 Shock
    • EN60068-2-64 Random Vibration
  • Able to withstand repeated 6 foot drops onto tiled floor while operating

Sidestream

  • Sample Rate: 50 m/L per minute
  • CO2 Measurement Range:
    • 0 - 150 mm Hg, 0 to 20 kPa
    • (at 760 mm Hg). Barometric Pressure
    • supplied by Host
  • CO2 Resolution:
    • 0.1 mm Hg 0 to 69 mm Hg
    • 0.25 mm Hg 70 to 150 mm Hg
  • CO2 Accuracy
    • 0 - 40 mm Hg 2 mm Hg
    • 41 - 70 mm Hg 5% of reading
    • 71 - 100 mm Hg 8% of reading
    • 101 - 150 mm Hg 10% of reading
    • Above 80 bpm 12% of reading
  • CO2 Stability
    • Short Term Drift: Drift over four hours shall not exceed 0.8 mm Hg max.
  • Long Term Drift: Accuracy specification will be maintained over a 120-hour period
  • Respiratory Rate Range: 2 to 150 bpm
  • Respiratory Rate Accuracy: 1 breath

Sample Cell/Filter

  • Proprietary single patient use sample cell and inline filter are integrated with the sample line which eliminates contamination of the internal system
  • Nasal Sampling Kits for Non-intubated Patients Adult, pediatric and infant nasal CO2 sampling, nasal CO2 sampling and O2 delivery
  • Adult and pediatric nasal/oral CO2sampling, nasal/oral CO2 sampling and O2 delivery
  • On-Airway Adapter KITS for Intubated Patients
  • Adult/Pediatric with and without dehumidification tubing Pediatric/ Infant, low dead space, with and without dehumidification tubing
  • Taper meets ISO 5356-1
  • Sample Kit Hours of Use
    • Nasal Cannula (all styles) — up to 12 hours
  • On-Airway Adapter Kits without dehumidification tubing — up to 12 hours
  • Sample Cell Detection
  • Insertion automatically turns sampling pump on. Removal automatically turns sampling pump off.
  • Water Resistance IPX4 -Splash-proof(when sample cell is inserted in sample cell receptacle)
  • Shock Impact IEC TR 60721-4-7 Class 7M3(designed to withstand environments subject to significant vibrations or high shock levels)
  • EN60068-2-27 Shock
  • EN60068-2-64 Random vibration
7

Accessories & Supplies

Price

3-Lead ECG Snap Set Leadwires

85003S

Web ID: 513

$21.85

Price

3-Lead ECG Adapter Cable - DIN to Banana

P00082

Web ID: 468

$35.95

Price

5-Lead Patient Cable for Hewlett Packard Codemasters and Merlin Monitors w/12 Pin Connectors

P00080

Web ID: 480

$175.00

Price

Replaceable Veterinary Alligator Clip Compatible with Waveline

<span>$</span>50<sup>.00</sup>

Web ID: 9892

$50.00

Price

Battery for Waveline Pro

66011BAT

Web ID: 9894
Price

CAPNOSTAT 5 Mainstream CO2 Sensor

P02212

Web ID: 12282

$1695.00

Catalog

Help & Settings

Equipment

See all

Supplies

See all