Avante True ECG 12T Twelve Channel Touch Screen EKG System

Avante

Avante True ECG 12T Twelve Channel Touch Screen EKG System

Web ID: 9665
Product Number: 60136TRS

Need help choosing?

Speak to one of our expertly trained specialists!

Need help Financing?

Check out financing options from OnePlace Capital.

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

  • Preview report for both real-time printing and file storage
  • Average template waveform with accurate interpretation tested with CSE DATABASE, which supplies measurement, diagnosis, and Minnesota code
  • Doctor can edit the printing style, printing speed, sensitivity, and used filter to get better waveforms instead of repeating patient examination
  • Freeze and review waveform timely to grasp every arrythmia
  • Internal storage including waveforms, measurement and diagnosis which could also be enlarged by flash disk or PC hard disk.
  • Features 8.4” color touch-screen
  • Compact, lightweight design with carrying handle
  • Digital filters for baseline, AC and EMG interference resistence
  • Standby mode for energy saving
  • Built-in Ethernet and RS-232 interfaces for PC connection
  • USB port for data transmission and external jet-printer connection
  • Internal Memory - 200 Tests
  • Built-in rechargeable Li-ion battery: voltage=14.4V - 5 hours, 400 Reports, 320 x 240 dots monochrome LCD
  • Available with PC-based ECG data management software

Specifications

  • Input circuit Defibrillation protection built-in
  • Lead Standard 12 leads
  • Acquisition mode 12-channel simultaneous
  • A/D converter 24 bits
  • Input voltage range 5mVp-p
  • Time constant >3.2s
  • Frequency response 0.05Hz-150Hz
  • Calibration voltage 1mV 2%
  • Sensitivity 2.5, 5, 10, 20, 10/5, AGC (mm/mV)
  • Input impedance >50M Ω (10Hz)
  • Input circuit current <10nA
  • Noise level <12.5 μ Vp-p
  • Patient leakage current <10 μ (220V-240V)
  • Patient auxiliary current <0.1 μ A (DC)
  • Filters EMG filter 25Hz/35Hz/45Hz/OFF Anti-baseline drift 0.05/0.15/0.25/0.5Hz Low-pass filter 150Hz/100Hz/ 75Hz AC filter 50Hz/60Hz
  • CMRR >121 dB
  • Recording modes Auto/manual/rhythm
  • Rhythm lead Single lead or three leads selectable
  • Safety Standard IEC I/CF
  • Power supply AC:100-240V, 50/60Hz
  • Battery Built-in rechargeable Li-ion battery: voltage=14.4V, for about 400 copies ECG printing
  • Recorder Thermal printer
  • Recording paper Roll and z-fold 216mm, 210mm width
  • Recording speed 5mm/s, 10mm/s12.5mm/s, 25mm/s,50mm/s (3%)
  • Dimensions 420mm x 330mm x 120mm
  • Display 800 x 600 dots LCD
  • External input >100K Ω, sensitivity 10mm/V±5
  • External output <100 Ω, sensitivity 1V/mV±5%
  • Communication interface Ethernet or RS232
1